Open Sniffer Firmware Upgrade
Feature-rich Analyzer For Zigbee / 6lowpan / 802.15.4 Networks And Iot Devices
Attention! Be sure that your power supply is stable. If you lose the power supply during the firmware upgrade process Open Sniffer needs to be re-flashed via JTAG programmer!
Fist of all, you should reset Open Sniffer to default settings
- Disconnect power cable.
- Push the Reset button and hold.
- Connect power cable.
- Wait 3 seconds then release the Reset button.
Firmware upgrade procedure
- Download and install LM Flash Programmer.
- Download an appropriate firmware from the Download page.
Please do not mix firmware for 1st. and 2nd. generation of Open Sniffer. - Connect Open Sniffer to your host PC via Ethernet cable.
- Configure host network adapter, IP address 10.10.10.1 and network mask 255.255.255.0.
- Run LM Flash Programmer as an Administrator.
- LM Flash Programmer -> Configuration panel -> Quick Set -> set Manual Configuration.
- LM Flash Programmer -> Interface -> select Ethernet.
- LM Flash Programmer -> Client IP Address and Client MAC Address put settings from the Open Sniffer homepage.
- LM Flash Programmer -> Ethernet Adapter select the host’s network interface where Open Sniffer is connected in (should start with 10.10.10.1).
- LM Flash Programmer -> Program tab -> Browse (point to firmware bin file)
- LM Flash Programmer -> Click on the Program button

Note: Firmware upgrade process starts after some delay (up 60 sec) if it is done for the first time.